Nortel Networks 1000M User Manual
Page 330
330
Connecting the telephones
WARNING
If connecting to a message waiting line card, unseat the
card from its assigned slot before continuing with the next
step.
3
Connect two NTAK9204 cables (one from connector J1 and one
from connector J2) from the protection module to the cross-connect
terminal.
Terminate the cables as shown in
telephone cross-connections" (page 326)
4
Cross-connect the J1 cable to the Tip and Ring connections coming
from the line card.
Refer to
"Preprogrammed data" (page 373)
for default DN
assignments.
5
Cross-connect the J2 cable to the off-premise telephone.
6
Install the regulatory label provided with the Off-Premise Protection
Module on the inside right-hand wall of the cabinet (near the Velcro
wriststrap fastener) or chassis.
7
Install the line card in its assigned position.
Now, you can activate the telephone, as described in
.
—End—
Nortel Communication Server 1000
Communication Server 1000M and Meridian 1 Small System Installation and Commissioning
NN43011-310
01.04
Standard
Release 5.0
13 May 2008
Copyright © 2008, Nortel Networks
.