Procedure 53 installing software – Nortel Networks 1000M User Manual
Page 280

280
Installing software
Note: IP Expansion Cabinet or Chassis software must be the same
software version as the Main Cabinet or Chassis.
CAUTION
CAUTION WITH ESDS DEVICES
Wear the antistatic wrist strap provided in the bottom of the cabinet
before handling circuit cards. Static electricity can damage the
components of power supplies and circuit cards.
Installing software on cabinets and chassis
Follow
Procedure 52 "Installing software" (page 280)
to install the software
on main cabinets and chassis.
For IP expansion, first install the software and customer database on the
Main Cabinet or Chassis, then follow
Procedure 53 "Installing software
for IP expansion, using the preprogrammed software daughterboard"
(page 290)
(to install from the preprogrammed software daughterboard)
or
Procedure 54 "Installing software for IP expansion, using a PC Card"
(to install from a PC Card) to install the software on Expansion
Cabinets or Chassis.
Procedure 52
Installing software
Step
Action
This procedure assumes that the system installation procedures in the
chapters
"Installing the Cabinet system" (page 75)
or
have been performed and that the system is up and
running.
In the menus and screens, there are references to Option 11 and Option
11E. These references do not apply to the Chassis system.
1
Make sure the SSC card is in CPU slot (slot 0) of the Main Cabinet
or Chassis.
2
Observe the terminal screen.
If
Then
The following is displayed:
SOFTWARE INSTALLATION
PROGRAM
Go to
.
Nortel Communication Server 1000
Communication Server 1000M and Meridian 1 Small System Installation and Commissioning
NN43011-310
01.04
Standard
Release 5.0
13 May 2008
Copyright © 2008, Nortel Networks
.