Table 52 power failure transfer unit connections, For pftu – Nortel Networks 1000M User Manual
Page 348
![background image](/manuals/191775/348/background.png)
348
Connecting the trunks
Table 52
Power Failure Transfer Unit connections
QUA6 J1 cable
Function
Pair
Color
Connects to
Comments
5T
5R
W-S
S-W
Connect to the telephone
6T
6R
R-BL
BL-R
Connect to the telephone line
card
Connect to TN assigned to the
telephone
7T
7R
R-O
O-R
Connect to the Central Office
trunk
P
F
T
1
8T
8R
R-G
G-R
Connect to the trunk line card
Connect to TN assigned to the
trunk
9T
9R
R-BR
BR-R
Connect to the telephone
10T
10R
R-S
S-R
Connect to the telephone line
card
Connect to TN assigned to the
telephone
11T
11R
BK-BL
BL-BK
Connect to the Central Office
trunk
P
F
T
2
12T
12R
BK-O
O-BK
Connect to the trunk line card
Connect to TN assigned to the
trunk
13T
13R
BK-G
G-BK
Connect to the telephone
14T
14R
BK-BR
BR-BK
Connect to the telephone line
card
Connect to TN assigned to the
telephone
15T
15R
BK-S
S-BK
Connect to the Central Office
trunk
P
F
T
3
16T
16R
Y-BL
BL-Y
Connect to the trunk line card
Connect to TN assigned to the
trunk
17T
17R
Y-O
O-Y
Connect to the telephone
18T
18R
Y-G
G-Y
Connect to the telephone line
card
Connect to TN assigned to the
telephone
19T
19R
Y-BR
BR-Y
Connect to the Central Office
trunk
P
F
T
4
20T
20R
Y-S
S-Y
Connect to the trunk line card
Connect to TN assigned to the
trunk
Nortel Communication Server 1000
Communication Server 1000M and Meridian 1 Small System Installation and Commissioning
NN43011-310
01.04
Standard
Release 5.0
13 May 2008