Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual
Page 707

Patch AMP
Chapter 41
41-5
Parameter
Patch AMP Value
Default Value
Parameter Name
83
L
Roughing cycle threshold depth
0.00000 in
0.00000 to 393.69685 inch
86
DAC monitor servo card 1
or 9/230 controls
Disabled
0 -- Disabled
1 -- Enabled
87
DAC monitor servo card 2
Disabled
0 -- Disabled
1 -- Enabled
111
L
Min infeed in multi threading
0.00000 mm
0.00000 to 9999.90000 mm
112
L
Finish allow in mult threading
0.00000 mm
0.00000 to 9999.90000 mm
113
L
Retract amount in grooving
0.00000 mm
0.00000 to 9999.90000 mm
130
Number of Motors on 1st Board
2
1 to 4
133
DAC monitor servo card 3
Disabled
0 -- Disabled
1 -- Enabled
134
Number of Motors on 2nd Board 0
1 to 4
140
Adapter Baud Rate
57.6K
0 -- 57.6K
1 -- 115.2K
2 -- 230.4K
141
Adapter Rack Number
1
0 to 59
142
Adapter Rack Size
FULL
0 -- 1/4 rack
1 -- 1/2 rack
2 -- 3/4 rack
3 -- Full rack
143
Adapter Start Module Group
SQ0
0 -- SQ0
1 -- SQ1
2 -- SQ2
3 -- SQ3
144
Adapter Last Rack Status
Not Last Rack
0 -- Not Last Rack
1 -- Last Rack
204
Tool offset cancel
Cancel Geom & Wear
0 -- Do not Cancel
1 -- Cancel Wear Only
2 -- Cancel Geom & Wear
206
Position tolerance for Skip 1
1.00000 mm
0.00000 to 100.00000 mm
207
Position tolerance for Skip 2
1.00000 mm
0.00000 to 100.00000 mm
208
Position tolerance for Skip 3
1.00000 mm
0.00000 to 100.00000 mm
209
Position tolerance for Skip 4
1.00000 mm
0.00000 to 100.00000 mm
399
Manual ACC/DEC mode
Exponential
0 -- Exponential
1 -- Linear
402
Positioning ACC/DEC mode
Linear
0 -- Exponential
1 -- Linear or S--Curve as per G--Code
405
Minimum feed reduction %
80 %
0 to 100 %
408
External decel speed (cutting)
0.42333 mm/sec
0.00000 to 169.33333 mm/sec
409
Corner override distance (DTC)
2.54000 mm
0.00000 to 9999.99999 mm
410
Corner override distance (DFC)
2.54000 mm
0.00000 to 9999.99999 mm