Jog Parameters

Chapter 8

8-4

Function

This parameter sets the resolution of the HPG (distance the axes travels per

HPG pulse) when performing an HPG jog with on

the MTB panel set to the MEDL X10.

Axis

Parameter

Number

Axis

Parameter

Number

(1)

[1356]

(7)

[7356]

(2)

[2356]

(8)

[8356]

(3)

[3356]

(9)

[9356]

(4)

[4356]

(10)

[10356]

(5)

[5356]

(11)

[11356]

(6)

[6356]

(12)

[12356]

Range

Pulse Count Multiplier - Low value to Pulse Count Multiplier - High value

The maximum and minimum values that may be set for this parameter are

dependant on the value set for the parameters “Pulse Count Multiplier -

Low” and “Pulse Count Multiplier - High.”

Notes

You must set this parameter independently for each axis.

The default setting for on the pushbutton MTB

panel is LOW X1.

8.1.2

Pulse Count Multiplier-Med