beautypg.com

5 largest jog increment – Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual

Page 276

background image

Jog Parameters

Chapter 8

8-18

Function

The value specified for this parameter is equal to the distance that an

incremental jog move travels when on the MTB

panel is set to HIGH X10000.

Axis

Parameter Number

Axis

Parameter Number

(1)

[1364]

(7)

[7364]

(2)

[2364]

(8)

[8364]

(3)

[3364]

(9)

[9364]

(4)

[4364]

(10)

[10364]

(5)

[5364]

(11)

[11364]

(6)

[6364]

(12)

[12364]

Range

Fourth Jog Increment to 127000.00000 mm or degrees

or

Fourth Jog Increment to 5000.00000 inch

The minimum value that may be set for this parameter is dependant on the

value set for the parameter Fourth Jog Increment.”

Notes

You must set this parameter independently for each axis.

The default setting for on the pushbutton MTB

panel is LOW X1.

8.4.5

Largest Jog Increment