Acc/Dec Parameters

Chapter 10

10-12

Range

0.00000 to 20,000.00000 mm/sec/sec

or

0.00000 to 787.4015 inch/sec/sec

or

0.00000 to 20,000.00000 deg/sec/sec

Notes

This parameter must be set independently for each axis.

Important: If the Servo Position Loop Type parameter (chapter 7) is set

for “ZFE Closed Loop” and the Feed Forward Percentage is set relatively

high, then it is important that the axis acceleration and deceleration

ramping closely match the “natural response” of the axis.

This is a simplified procedure for determining the Acc Ramp value in

cases where it is critical to axis performance:

Figure 10.6

Matching S--Curve Acc Ramp to the Natural Response of the Axis

Time (seconds)

Feedrate

Rapid

Natural response

curve of axis

S--Curve Acc Ramp