14 scaling allowed – Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual
Page 654
Miscellaneous Parameters
Chapter 37
37-14
Possible solutions include:
- alter your part program by removing or combining consecutive
nonmotion blocks that occur during cutter compensation, QPP, or
Corner/Chamfer blocks.
- reduce the Cutter Compensation Maximum Non--Motion Block
Limit in AMP (note this may change your compensation contour).
- lower the AMPed number of retrace blocks available.
- purchase more RAM.
Contact Allen-Bradley customer service for assistance on determining the
proper solution for your system.
This is a global parameter; the value set here applies to all axes. For Dual
Processing controls, this is a per process parameter. The value set with this
parameter applies to all of the axes assigned to that process.
Function
Use this parameter to specify whether scaling is allowed on a specified
axis. When this parameter is set “TRUE ” for an axis, scaling may be
applied to that axis. When this parameter is set “FALSE ” for an axis,
scaling may not be applied to that axis. Use this parameter only if the
scaling option is installed.
Refer to your programming and operation manual for more information.
Axis
Parameter
Number
Axis
Parameter
Number
(1)
[1100]
(7)
[7100]
(2)
[2100]
(8)
[8100]
(3)
[3100]
(9)
[9100]
(4)
[4100]
(10)
[10100]
(5)
[5100]
(11)
[11100]
(6)
[6100]
(12)
[12100]
Range
Selection
Result
(a)
True
(b)
False
Notes
This parameter must be set independently for each axis.
37.14
Scaling Allowed