beautypg.com

3 pal analog output port control parameters – Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual

Page 453

background image

PAL Parameters

Chapter 20

20-3

Function

Use the PAL analog output port control parameters to assign an analog

output port on the servo module(s) (or processor board for the 9/230) of the

control to one of the PAL analog output control flags ($AOUT00

-$AOUT03). PAL can control up to four analog output ports. Only one

analog output port can be assigned to each PAL analog output port control

parameter. Refer to your PAL reference manual for more details.

PAL-controlled analog output ports must not be defined in AMP as an

analog output port assigned to a fitted axis or a spindle. On the 9/260 and

9/290, PAL cannot control the analog output ports on a servo module (or

processor board for the 9/230) unless there is at least one fitted axis

assigned to that servo module in AMP. On the 9/230, at least one axis must

be fitted to use PAL analog outputs.

Important: For 9/260 and 9/290 controls, the sum total of fitted axes,

spindles, and PAL controlled analog output ports on one servo board, as

defined in AMP, cannot exceed the actual number of output ports on that

servo board. Also, do not include the number of PAL-controlled analog

output ports when determining the value of the parameters Number of

Motors on 1st Board or Number of Motors on 2nd Board.

Parameter

Parameter

Number

Corresponding PAL Analog

Output Port Control Flags

PAL $AOUT00-analog output port

[890]

$AOUT00

PAL $AOUT01-analog output port

[891]

$AOUT01

PAL $AOUT02-analog output port

[892]

$AOUT02

PAL $AOUT03-analog output port

[893]

$AOUT03

20.3

PAL Analog Output Port

Control Parameters