Home Parameters
Homing refers to the process of orienting a linear or rotary axis to a
specific, repeatable, mechanical position. This chapter covers the AMP
parameters that the control uses to home the axes.
If you have configured your axis as open loop, servo off, or servo
detached, you do not need to set the parameters in this chapter. Refer to
Chapters 7 and 8 for more information on Digital or Analog Servo
Parameters.
Access these parameters by selecting the “Home Parameters” group on the
AMP main menu screen.
Proj:
AMPTEST
Appl:
AMP
Util:
Edit
F2-Project F3-Application F4-Utility
F5-Configuration
F1-File
F2-Axis
F3-Options
F4-Quick Edit!
F5-Process
Type : Lathe
AXIS: X
P1:
File : TEST
-
Home
Parameters
-
Dir. to Move Off Limit Switch (1)
: negative direction off switch
Home Calibration (1)
: 0.00000 mm
Axis Position after Homing (1)
: 0.00000 mm
Home Speed from Limit Switch (1)
: 254.0004 mmpm
G28 Direction to Home (1)
: plus
G28 Home Speed (1)
: 254.0000 mmpm
G30 Secondary Home Position (1)
: 0.00000 mm
G30 3rd Home Position (1)
: 0.00000 mm
G30 4th Home Position (1)
: 0.00000 mm
Machine Pos. at DCM Scale 0 (1)
: 0.00000 mm