Plane Select Parameters
Chapter 18
18-4
Function
Use this parameter to determine the first primary axis that is used to make
up the plane called by G17, G18, or G19. This parameter sets which axis
is first in the plane. For example, if the G17 plane is to be set as the XY
plane, “G17 primary axis 1” should be set as X. If the G17 plane is to be
set as the YX plane, “G17 primary axis 1” should be set as Y.
A value for this parameter may be chosen from these allowable axis
names: A, B, C, U, V, W, X, Y, Z, $B, $C, $X, $Y, or $Z. A value of
“None” may also be selected indicating that the plane that is selected with
that G-code is not used.
Parameter
Parameter Number
Single
Mill
Dual Mill
Process 1
Dual Mill
Process 2
Single
Lathe
Dual Lathe
Process 1
Dual Lathe
Process 2
G17 primary axis 1
[541]
[20541]
[21541]
[570]
[20570]
[21570]
G18 primary axis 1
[547]
[20547]
[21547]
[547]
[20547]
[21547]
G19 primary axis 1
[553]
[20553]
[21553]
[576]
[20576]
[21576]
Range
Selection
Results
Selection
Results
(a)
A
(i)
Z
(b)
B
(j)
$B
(c)
C
(k)
$C
(d)
U
(l)
$X
(e)
V
(m)
$Y
(f)
W
(n)
$Z
(g)
X
(o)
none
(h)
Y
Notes
This is a global parameter; the value set here applies to all axes.
For Dual Processing controls, this is a per process parameter. The value set
in the parameters applies to all of the axes assigned to that process.
18.2
(G17, G18, G19) Primary