Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual
Page 45

Using AMP Applications and ODS Utilities
Chapter 2
2-19
When you press any key, the workstation displays this screen:
Proj:
TEST
Appl:
Download
Util: Send AMP params
F2-Project F3-Application F4-Utility
F5-Configuration
F1-File
Downloading...
Use ARROW keys or type in name. Press ENTER when done or ESC to cancel
AMP1
AMP2
AMP3
7.
Select or type in an AMP file name.
The workstation displays the message:
Waiting for response on the control
The control displays the message:
OKAY TO DOWNLOAD? [Y/N] :
You must respond by pressing
[Y]
or
[N]
, and then by pressing the
[TRANSMIT]
key on the controls operator panel keyboard.
If you are using a transfer line control type the control automatically
sends the ODS workstation the Y (okay to download) response
without prompting on the CRT. This transfer line feature allows
AMP and PAL to be updated without the need for an operator panel
being attached to the system. If you don’t have the transfer line
option, you can set PAL for automatic download with the $FDNLD
flag. Refer to your PAL reference manual for more information.
8.
Refer to the table below.
If you want to:
press:
the workstation:
abort the download procedure
[N]
aborts the download procedure
halt all control functions
[Y]
downloads the selected AMP file to the control