Acc/Dec Parameters
Chapter 10
10-7
Axis
Parameter
Number
Single Process
All
[402]
Notes
This is a global parameter. The value set here applies to all axes.
Axis jogging moves use either linear or exponential Acc/Dec as defined in
AMP via Manual Acc/Dec (refer to page 10-19 for more information about
Manual Acc/Dec). Axis cutting moves use Linear or S--Curve Acc/Dec.
Function
If two adjacent motion blocks in a program require different axis feedrates,
Acc/Dec may be necessary to smooth the speed transition. The value
entered for this parameter specifies the maximum change in feedrate that
will be executed without any Acc/Dec activated.
For example, entering 50 mmpm here, means that any feedrate changes
equal to or less than 50 mmpm will be executed as a step, with no
Acc/Dec. Acc/dec ramping will be used for any feedrate transitions greater
than 50 mmpm.
ATTENTION: Entering too large a value here may result in
damage to the part, tooling, or machine. Large changes in
feedrate should always be made gradually when using Acc/Dec.
For most axis configurations, this value should be less than or equal to the
value entered for the Acc/Dec Ramp parameter.
Axis
Parameter
Number
Axis
Parameter
Number
(1)
[1204]
(7)
[7204]
(2)
[2204]
(8)
[8204]
(3)
[3204]
(9)
[9204]
(4)
[4204]
(10)
[10204]
(5)
[5204]
(11)
[11204]
(6)
[6204]
(12)
[12204]
10.3
Velocity Step for ACC/DEC