Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual
Page 42

Using AMP Applications and ODS Utilities
Chapter 2
2-16
4.
Refer to the table below.
If you want to:
select:
the workstation:
· discard any changes
· close the open file
[Y]
· exits the AMP editor
· returns to the main menu line of ODS
terminate the quit procedure
[N]
returns to the screen that was displayed
before the quit procedure started
After you have edited and saved the AMP file, download the file to the
control so that it becomes the currently active AMP file. Use the
download application of ODS to download AMP files in these ways:
from the workstation to the control
to a storage device, then from the storage device to the control
Important: If you are using a DH+ network to download AMP using the
pass through feature, see page 2-32 for details on enabling pass through.
When you download directly to the control, connect the workstation to the
control. Refer to your integration and maintenance manual for more
information.
When you use serial communications and download to a control with a
standard MTB panel, connect the interface cable to the serial
communication port on the front left side of the standard MTB panel. This
port is interfaced directly with port B on the processor.
Important: The 9/230 has only one serial port. It is labeled and configured
as Port B.
2.12
Downloading AMP Files
2.12.1
Downloading an AMP File
from the Workstation to the
Control