Chapter
10
10-1
Acc/Dec Parameters
This chapter covers the acceleration and deceleration AMP parameters for
the control.
Use acceleration and deceleration (Acc/Dec) parameters to control the
method and rate of speed change when an axis is starting or stopping.
When you select the “Acc/Dec Parameters” group from the main menu
screen in the AMP application, the workstation displays this screen:
Proj:
AMPTEST
Appl:
AMP
Util:
Edit
F1-File
F2-Axis
F3-Options
F4-Quick Edit!
F5-Process
Type:
Lathe
AXIS :X
-
linear
File :
TEST
- Acc/Dec Parameters -
Positioning ACC/DEC mode
: Linear or S-Curve as per G-code
Velocity step for ACC/DEC (1)
: 254.00000 mmpm
Linear Acceleration Ramp (1)
: 1524.00000 mmpm/s
Linear Deceleration Ramp (1)
: 1524.00000 mmpm/s
S-Curve Acceleration Ramp (1)
: 1524.00000 mmpm/s
S-Curve Deceleration Ramp (1)
: 1524.00000 mmpm/s
Manual Delay Constant (1)
: 3
Programmed Delay Constant
: 1
Manual ACC/DEC mode
: Exponential
Axis Jerk (1)
: 304.8000 mmpm/s/s
Minimum Programmable Jerk (1)
: 304.8000 mmpm/s/s
This chapter covers these Acc/Dec parameters:
Parameter:
Page:
Positioning Acc/Dec Mode
10-3
Velocity Step for Acc/Dec
10-7
Linear Acceleration Ramp
10-8
Linear Deceleration Ramp
10-9
S--Curve Acceleration Ramp
10-11
S--Curve Deceleration Ramp
10-13
Manual Delay Constant
10-14
Programmed Delay Constant
10-17
Manual Acc/Dec Mode
10-19
Axis Jerk
10-21
Minimum Programmable Jerk
10-23
10.0
Chapter Overview