beautypg.com

3 pto g- code for modal group 6 – Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual

Page 436

background image

Power-up G-code Parameters

Chapter 19

19-4

Function

This parameter selects the default G-code for modal group 6. The selected

G-code specifies whether the control operates under inch or metric mode at

power -up only. A control reset will not re-establish this mode. The last

programmed state remains in effect.

Lathe

A

Lathe

B

Lathe

C

Mill

Control

Surface

Grinder

Cylindrical

Grinder

Active Mode

G20

G20

G70

G20

G70

G70

Inch system

G21

G21

G71

G21

G71

G71

Metric system

Axis

Parameter Number

Single Process

Process 1

Process 2

All

[526]

[20526]

[21526]

Range

Selection

Result

(a)

Inch mode

(b)

Metric mode

Notes

This is a global parameter. The value set here applies to all axes.

For dual--processing controls, this is a per process parameter. The value set

in the parameters applies to all of the axes assigned to that process.

19.3

PTO G- code For Modal

Group 6