beautypg.com

3 velocity feedback counts/cycle – Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual

Page 211

background image

Servo Parameters

Chapter 7

7-65

If not, an error will occur upon powering up the control after downloading

AMP.

This parameter must be set independently for each axis.

Function

Important: The standard servo feedback configuration uses one feedback

device for both positioning and velocity data. If this is the case on your

system, this parameter must be set to the same value as the parameter

Position Feedback Counts/Cycle. Refer to this chapter’s overview for an

example of a system that uses two feedback devices for the same axis and

may require a different value be selected here.

Important: Though the analog servo interface does not support a separate

feedback device for the velocity loop, you must still configure these

velocity loop parameters including Velocity Loop Feedback Port,

Velocity Loop Feedback Type, Velocity Feedback Counts/Cycle, and

Sign of Velocity Feedback. These parameters must be set to the same

values as their positioning loop counterparts.

Velocity Feedback Counts/Cycle specifies the number of counts that are

produced by the velocity encoder for each electrical cycle (usually the

same number of counts as set with the parameter Position Feedback

Counts/Cycle as they are typically the same encoder). For encoders with

one marker, an electrical cycle is one revolution. For encoders with two

markers, an electrical cycle is one half revolution.

Important: Spindle encoders must have only one marker per revolution.

Encoders are generally labeled with the number of lines they have per

electrical cycle. Since encoders used with the control must have two

feedback channels (A and B) positioned in quadrature, the number of

counts produced is actually 4 times the number of lines.

Velocity Feedback Counts/Cycle = counts/elec. cycle = 4 x lines/elec.
cycle

Axis

Parameter

Number

Axis

Parameter

Number

(1)

[1565]

(7)

[7565]

(2)

[2565]

(8)

[8565]

(3)

[3565]

(9)

[9565]

(4)

[4565]

(10)

[10565]

(5)

[5565]

(11)

[11565]

(6)

[6565]

(12)

[12565]

7.3.3

Velocity Feedback

Counts/Cycle