beautypg.com

Allied Telesis AlliedView-EMS 4.0.3 Device-Management User Manual

Page 94

background image


AlliedView™-EMS 4.0.3 Device Management Guide

Page 94 of 468


Aggregation Port Info

Displays a list of Link Aggregation Control configuration parameters for each

Aggregation Port on this device.

Note

- The current firmware version does not allow the Actor

Administrative Key and Partner Administrative System ID parameters to be

configured.

Note

- Device Manager does not handle 8-bit string parameters correctly. As

a result, the Actor Administrative Status and Partner Administrative Status

parameters will display unrecognizable values and will not be configurable.

The Actor Operational Status and Partner Operational Status parameters

will also display unrecognizable values.


Storm Control

Basic Info

Displays basic information about storm control.


Storm Control Protection

Displays information about the storm control protection per port.

Note

- The current firmware version does not allow the following parameters to be

configured:

Rate Type

Unkown Unicast Rate

Unkown Multicast Rate

Multicast Rate

Note

- Only the Broadcast Enable and Multicast Enable parameters can be

configured.


Storm Control Group

Displays information about group id for each supported frame type defined

per port.