Telnet Sessions
Displays the login time, client IP address and telnet session status.
CLI Info
Displays information if the file is enabled or not.
LCLI Info
Displays information about the device's Telnet sessions and SSH
sessions if enabled or not.
Note
- Valid MIB Set values for History Size, Telnet History Size and
SSH History Size parameters should range from 10 to 210. However,
the current firmware version allows the user to enter values up to
246.
RS-232
Displays the configuration of the baud rate of the device.
Web Server
Displays the configuration about the HTTP and HTTPS Port the device used.
Web Info
Displays embedded Web protocol.
Note
- Setting the HTTP Port and HTTPS Port parameters to '0' will
automatically set the parameters to their default port numbers which
are 80 and 443 respectively.
Web Services
Displays the services used for the embedded Web protocol.
Note
- The current firmware version does not allow Service Protocol
parameter to be configured.
Note
- Valid MIB Set values for Service Certificate ID parameter should
range from 0 to 1000. However, the current firmware version allows
user to enter values in the range [-2147483648 to 2147483647]
inclusive. Attempting to enter values greater than 2147483647 will
cause the new value to be converted to its equivalent wrap-around
value; i.e., 2147483648 will become -2147483648, 2147483649 will
become -2147483647, and so on.