Allied Telesis AlliedView-EMS 4.0.3 Device-Management User Manual
Page 29

AlliedView™-EMS 4.0.3 Device Management Guide
Page 29 of 468
Note
- To collect statistical data on an interface, do the following using a MIB
browser tool that allows you to issue an SNMP Set request on a specific
table element:
•
Set the etherStatsStatus (1.3.6.1.2.1.16.1.1.1.21) object to
"createRequest(2)"
•
Set the etherStatsDataSource (1.3.6.1.2.1.16.1.1.1.2) object to the OID
of the Ethernet interface to monitor (e.g. 1.3.6.1.2.1.2.2.1.1.1 - Port 1)
•
Set the etherStatsStatus object to "valid(1)"
Additional Info
Displays additional traffic statistics in the network segment such as frames
received/sent, collisions, broadcast frames and multicast frames.
Note
- The Deferred Transmissions parameter is not applicable to the AT-
8000/8POE and should be ignored.
Error
Displays error statistics in the network segment such as CRC errors,
alignment errors, bad frames received late collisions and total transmit
errors.
History Control Table
Displays the RMON History table.
Note
- To maintain a history of statistics taken at particular intervals for an interface,
do the following using a MIB browser tool that allows you to issue an SNMP Set
request on a specific table element:
•
Set the historyControlStatus (1.3.6.1.2.1.16.2.1.1.7) object to
"createRequest(2)"
•
Set the historyControlDataSource (1.3.6.1.2.1.16.2.1.1.2) object to the OID of
the Ethernet interface for which historical data will be collected (e.g.
1.3.6.1.2.1.2.2.1.1.1 - Port 1)
•
Set the historyControlStatus object to "valid(1)"
Alarm Table
Displays the RMON Alarm table.
Event Table
Displays the RMON Event table.
Event Log
Displays the RMON Event log.