Note

- Valid MIB Set values for the Data Pattern parameter should range

from 1 to 4294967295. However, the current firmware version does not

allow Device Manager to display the correct value greater than 2147483647.

Attempting to enter values greater than 2147483647 will cause the new
value to be converted to the following values:

4286578688 - 4294934527: 8388608 - 16744447

4294934528 - 4294967167: 32768 - 65407

4294967168 - 4294967295: 128 - 255

Note

- Device Manager does not handle objects of type OCTET STRING

correctly. As a result, the Address parameter will not be configurable and

will display a sequence of bytes in hexadecimal format instead of the actual
destination of ping packets.


Ping Statistics

Displays statistics of the Ping polling.

Security Menu

From the Security menu, you can view and edit port access entity information such as the

PAE port information and the Supplicant PAE information.

Port-based Authentication

Authentication Status

Displays the status of the port-based authentication.


PAE Port Info

Standard

Displays standard PAE port information.

Note

- Device Manager does not handle objects of type BITS correctly. As a

result, the Capabilities parameter will display an 8-bit binary string instead of

the actual PAE functionality supported. However, the PAE functionality

supported can still be determined by looking at the bits that are on from

right to left:

Bit 0 - Authenticator

Bit 1 - Supplicant


Enterprise

Displays enterprise PAE port information.