beautypg.com

Allied Telesis AlliedView-EMS 4.0.3 Device-Management User Manual

Page 226

background image


AlliedView™-EMS 4.0.3 Device Management Guide

Page 226 of 468

Rapier G6F-SX/MT

Device Manager LEDs for Rapiers

LED

State

Description

PWR Green

Red

The switch is receiving power from the main power supply.

The main power supply has failed.

RPS Green

Red

Gray

The switch is receiving power from the redundant power supply.

RPS has failed.

RPS is not installed or RPS monitoring is disabled.

DUPLEX Green

Orange

The port is operating at full duplex.

The port is operating at half duplex.

Note

- The current firmware version does not allow Device Manager to support the

Reset button.

Note

- Please refer to Uplink Modules for the operations and behavior of the uplink

modules installed in these devices.

Note

- Please refer to Network Service Modules for the operations and behavior of the

Network Service Modules installed in these devices.

Note

- To turn RPS monitoring on or off on the switch, enter the command SET SYSTEM

RPSMONITOR={ON|OFF} from the command line interface. To see whether RPS

monitoring is on, use the command SHOW SYSTEM. To turn on RPS monitoring using

SNMP, set the fanAndPsRpsMonitoringStatus variable to on.