AlliedView™-EMS 4.0.3 Device Management Guide

Page 387 of 468

Ping Results

Displays the results of the performed ping operations in the Ping Control

table.

Note

- Device Manager does not handle objects of type OCTET STRING

correctly. As a result, the Target IP Address parameter will display a

sequence of bytes in hexadecimal format instead of the actual IP address of

the remote host.

Note

- Device Manager does not handle objects of type OCTET STRING

correctly. As a result, the Last Good Probe parameter will display a sequence

of bytes in hexadecimal format instead of the actual date and time of day.

Note

- The current firmware version is unable to display any value for the

Owner Index and Test Name parameters.

Note

- The current firmware version returns the value '???(3)' for the

Operational Status parameter when the Admin Status parameter in the Ping

Control table is set to enabled.


Ping Probe History Table

Displays ping probe history in performing ping operations.

Note

- The current firmware version returns a 'noSuchName' value for the

Ping Probe History Table parameters.


Restart Device

Initiates a restart on the switch.

Note

- For devices that is set to standalone mode, while the Reset operation is in

progress, error "The error with 'Set' operation. Error: time out occurred." will be

displayed and should be ignored.


Telnet

Starts a Telnet connection to the switch.


WEB Browser

Connects to the switch's HTTP server.