Note

- Device Manager does not handle objects of type BITS correctly. As a result,

the MED TLVs Tx Enable parameter will not be configurable and will display

an 8-bit binary string instead of the actual TLV types allowed. However,
the TLV types allowed can still be determined by looking at the bits that are

on from left to right:

Bit 0 - Capabilities

Bit 1 - Network Policy

Bit 2 - Location

Bit 3 - Extended PSE

Bit 4 - Extended PD

Bit 5 - Inventory

Network Policy Info

Displays information about a particular policy on a specific port component.

Note

- Device Manager does not handle bit string correctly. As a result, the

Application Type parameter will not be displayed.


Location Info

Displays the Location information as advertised by the local system.

Note

- Device Manager always treats objects of type OCTET STRING as a

sequence of bytes in hexadecimal format and does not convert them to plain

text format when necessary. As a result, the Location parameter will neither

be readable nor configurable.


POE Info

Displays the defined type of Power over Ethernet advertised by the local

device.


POE/PSE Port Info

Displays a table that contains one row per port of PSE/PoE information on

the local system known to this agent.


Policy Container Config

Displays the configuration of a particular policy in the media policy container.

Note

- Configuring the Row Status parameter to any invalid values will not

return an error message.

Note

- Device Manager always treats objects of type OCTET STRING as a

sequence of bytes in hexadecimal format and does not convert them to plain

text format when necessary. As a result, the Port Number parameter will

neither be readable nor configurable.