Ping Polling
Ping Status
Displays the status of the Ping polling.
Note
- Since the Address parameter cannot be configured, the Ping Status
parameter cannot also be configured.
Ping Parameters
Displays basic information of the Ping module.
Note
- The current firmware version accepts values in the range
[1-4294967595] inclusive for the Number of Packets and Time Interval
parameters.
Note
- Valid MIB Set values for the Timeout parameter should range from
1 to 65535. However, the current firmware version allows the user to enter
values in the range [-65535 to -1, 1 to 65535] inclusive. Attempting to enter
values greater than 65535 will cause the new value to be converted to its
equivalent wrap-around value; i.e., 65536 will become 0, 65537 will become 1,
and so on.
Note
- Valid MIB Set values for the Number of Packets parameter are in the
range [1-4294967295] inclusive. However, attempting to enter values greater
than 2147483647 will cause the new value to be converted to its equivalent
wrap-around value; i.e., 2147483648 will become -2147483648, 2147483649
will become -2147483647, and so on.
Note
- Device Manager does not handle objects of type OCTET STRING
correctly. As a result, the Address parameter will not be configurable and
will display a sequence of bytes in hexadecimal format instead of the actual
destination of ping packets.
Ping Statistics
Displays statistics of the Ping polling.
Reset Cold
Initiates a cold restart on the switch.
Reset Warm
Initiates a warm restart on the switch.
Reset Info
Displays information about the restart.
Telnet
Starts a Telnet connection to the switch.