beautypg.com

Allied Telesis AlliedView-EMS 4.0.3 Device-Management User Manual

Page 335

background image


AlliedView™-EMS 4.0.3 Device Management Guide

Page 335 of 468

Note

- Valid MIB Set values for the Port Path Cost Config parameter

is [1-200000000] inclusive. However, the current firmware version allows

the user to set this parameter to '0' as its value and will automatically set the
entered value to valid values.

Note

- The current firmware version does not allow the Protocol Migration,

Edge Port, Point-to-Point Config and Port Path Cost Config parameters to be

configured.


MAC Control Pause

Displays information about the MAC Control Pause function on a single ethernet-

like interface.

Note

- The current firmware version returns a 'noSuchName' value for the Received

Frames (HC) and Transmit Frames (HC) parameters.

Note

- The PAUSE Config parameter is implemented as 'read-only'.


MAU Info

Displays interface-related MAU information for the port.

Note

- The MAU Status and Default MAU Type parameters are implemented as

'read-only'.

Note

- The MAU Type List parameter is not applicable to the AT-x600 series and

should be ignored.

Note

- The Mau Type List Bits and HC False Carriers parameters are not applicable

to the AT-x600 series and should be ignored.

Note

- The current firmware version returns the value 'NULL' for the MAU Type

and Default MAU Type parameters.


MAU Negotiation Info

Displays the MAU's auto-negotiation settings and its status.

Note

- The Administration Status and Restart parameters are implemented as 'read-only'.

Note

- The Advertised Negotiation Capability parameter is not applicable to the

AT-x600 series and should be ignored.

Note

- The Negotiation Capability, Advertised Negotiation Capability and Received

Negotiation Capability parameters are not applicable to the AT-x600 series and

should be ignored.