Allied Telesis AlliedView-EMS 4.0.3 Device-Management User Manual
Page 340

AlliedView™-EMS 4.0.3 Device Management Guide
Page 340 of 468
Note
- Valid MIB Set values for the System Name parameter is up to 255
characters. However, values exceeding 64 characters will be truncated.
Note
- The current firmware version allows the System Name parameter to
be set to 'NULL'. However, attempting to set this parameter to value 'NULL'
will set it to its default value 'awplus'.
Enterprise
CPU Utilization
Displays information about the CPU utilization over different periods
of time.
Fan Speeds
Displays information about fans installed in the device that have their
fan speeds monitored by environment monitoring hardware.
Voltage Rails
Displays information about voltage rails in the device that are
monitored by environment monitoring hardware.
Temperature Sensors
Displays information about the temperature monitored by the
temperature sensors in the device.
Power Supply Bay Sensors
Displays information about the environment monitoring sensors on
devices installed in power supply bays.
LED Faults
Displays information about the LEDs on the device.
Contact Details / Memory
Displays Contact Details information and Memory information of the
device.
Host Resources
General System Info
Displays general information about the host resources.
Note
- Device Manager does not handle objects of type OCTET STRING
correctly. As a result, the Time and Date parameter will display a sequence
of bytes in hexadecimal format instead of the actual date and time of day.
Note
- The Time and Date, Initial Load Device and Initial Load Parameter
parameters are implemented as 'read-only'.
Logical Storage Areas
Displays resource information about the storage devices.