Allied Telesis AlliedView-EMS 4.0.3 Device-Management User Manual
Page 269

AlliedView™-EMS 4.0.3 Device Management Guide
Page 269 of 468
Note
- L3 Models: The current firmware version does not allow the Port Speed and
Port Duplex parameters to be configured to the desired port speed and duplex
mode. As a result, the speed label that will be displayed on the port image and its
corresponding DUP LED will depend on the actual speed and duplex mode detected
by the device.
Note
- AT-94xxTs/XP: The current firmware version returns the value 'unknown' for
the Port Speed parameter of the XFP ports.
Note
- L3 Models: The current firmware version does not return any Set Error when
setting the Port Speed and Mode parameter of SFP/RJ-45 combo ports to 1Gbps
half-duplex.
Enable
Enables the port.
Disable
Disables the port.
Port Trunking
Displays Port Trunking information as returned by the device and allows the
configuration of trunk name, method and port list.
Note
- The current firmware version allows the Trunk Name parameter to be
configured.
Note
- L3 Models: The current firmware version does not return any Set Error when
configuring the Row Status parameter to 'not in service'.
Note
- L3 Models: The current firmware version does not return any Set Error when
configuring the Port List parameter to invalid values.
Port Mirroring
Displays Port Mirroring parameters and allows you to create/delete a port mirror.
Note
- The Mirroring Source Module, Mirroring Source Port and Mirroring
Destination Module parameters are not applicable to the AT-9400 series and should
be ignored.
Note
- L2+ Models: The current firmware version does not allow the Mirroring
Source Port (Ingress) and Mirroring Source Port (Egress) parameters to be set to
NULL.
Note
- L3 Models: The current firmware version does not return any Set Error when
configuring the Mirroring Source Port (Ingress) and Mirroring Source Port (Egress)
parameters to invalid values.