Allied Telesis AlliedView-EMS 4.0.3 Device-Management User Manual
Page 411

AlliedView™-EMS 4.0.3 Device Management Guide
Page 411 of 468
Trigger
Trigger Info
Displays the trigger configuration information in the device.
Trigger Counters
Displays counters in activation of the triggers in the device.
Remote Ping
Ping Objects
Displays the maximum number of concurrent active ping requests.
Note
- The Target Address Type parameter is implemented as 'read-only'.
Ping Control
Defines the Ping Control Table for providing, via SNMP, the capability of
performing ping operations at a remote host.
Note
- Valid MIB Set values for the Data Size parameter should range from 0-
65507. However, the current firmware version does not allow this
parameter to be set to 0-7 as its value.
Note
- The current firmware version does not allow the Destination Port
Number parameter to be configured.
Note
- Device Manager does not handle objects of type OCTET STRING
correctly. As a result, the Data Fill parameter will display a sequence of bytes
in hexadecimal format instead of the actual input value.
Note
- The current firmware version does not allow Type parameter to be
configured.
Note
- Device Manager does not handle objects of type BITS correctly. As a
result, the Trap Generation parameter will not be configurable and will
display an 8-bit binary string instead of the actual trap generation options
allowed.
Note
- Device Manager does not handle objects of type OCTET STRING
correctly. As a result, the Target Address and Source Address parameter will
display a sequence of bytes in hexadecimal format instead of the actual input
value.
Ping Results
Displays the results of the performed ping operations in the Ping Control
table.
Note
- Device Manager does not handle objects of type OCTET STRING
correctly. As a result, the Target IP Address parameter will display a