Allied Telesis AlliedView-EMS 4.0.3 Device-Management User Manual
Page 173
AlliedView™-EMS 4.0.3 Device Management Guide
Page 173 of 468
Detail Info
Displays detailed port information such as duplex mode.
Note
- Valid MIB Set values for the Port Flow Control parameter are 'disable' and
'enable'. Attempting to set Port Flow Control to 'unknown' will cause the parameter
to be set to 'enable'.
Note
- Valid MIB Set values for the Port Back Pressure parameter are 'disable' and
'enable'. Attempting to set Port Back Pressure to 'unknown' will cause the
parameter to be set to 'enable'.
Note
- The Port CoS/QoS Priority parameter is not applicable to the AT-8500 series
and should be ignored.
Note
- AT-8550 : The current firmware version allows the Port Speed and Mode
parameter of a GBIC or SFP port to be set to '10Mbps full-duplex' or '100Mbps full-
duplex' even if the GBIC or SFP module inserted is not capable of 10/100 Mbps
connectivity.
Note
- AT-8550 : The 10/100/1000Base-T twisted pair ports cannot be manually set
to 1000Mbps. However, the current firmware version allows the Port Speed and
Mode parameter for these ports to be set to '1Gbps full-duplex' or '1Gbps half-
duplex'.
Note
- When the Port Speed and Mode parameter is set to 'auto sense', the Port
MDIO parameter is automatically set to 'mdi' and cannot be changed to 'auto mdix'
Note
- AT-8516F/SC: The Port Speed and Mode parameter of the 100Base-FX/SC
fixed ports can only be set to '100Mbps full-duplex'.
CoS
Displays Class of Service parameters and allows you to configure CoS for a port,
change the default mappings of CoS priorites to egress priority queues and configure
a scheduling method for Class of Service.
Note
- Valid MIB Set values for the CoS Queue parameters are:
•
egress-queue-0
•
egress-queue-1
•
egress-queue-2
•
egress-queue-3
Attempting to set these parameters to any other value will result in the error
message: "The error occurred with 'Set' operation. Error: bad value."
Note
- The current firmware version accepts values in the range [1-255] inclusive for
the Queue Weight parameters.