beautypg.com

Allied Telesis AlliedView-EMS 4.0.3 Device-Management User Manual

Page 214

background image


AlliedView™-EMS 4.0.3 Device Management Guide

Page 214 of 468

Note

- The current firmware version returns the value 'NULL' for the OID

parameter.


LLDP MED

Device Info

Displays information which describe the device's behavior of the LLDP-MED.


MED Port Config

Displays the LLDP configuration information that controls the transmission

of the MED.

Note

- Device Manager does not handle objects of type BITS correctly. As a

result, the TLVs Tx Enable parameter will not be configurable and will display

an 8-bit binary string instead of the actual TLV types allowed. However, the

TLV types allowed can still be determined by looking at the bits that are on

from left to right:

Bit 0 - Port Description

Bit 1 - System Name

Bit 2 - System Description

Bit 3 - System Capabilities

Note

- Device Manager does not handle objects of type BITS correctly. As a

result, the MED TLVs Tx Enable parameter will not be configurable and will

display an 8-bit binary string instead of the actual TLV types allowed.

However, the TLV types allowed can still be determined by looking at the

bits that are on from left to right:

Bit 0 - Capabilities

Bit 1 - Network Policy

Bit 2 - Location

Bit 3 - Extended PSE

Bit 4 - Extended PD

Bit 5 - Inventory

Network Policy Info

Displays information about a particular policy on a specific port component.

Note

- Device Manager does not handle bit string correctly. As a result, the

Application Type parameter will not be displayed.


Location Info

Displays the Location information as advertised by the local system.

Note

- Device Manager always treats objects of type OCTET STRING as a

sequence of bytes in hexadecimal format and does not convert them to plain

text format when necessary. As a result, the Location parameter will neither

be readable nor configurable.