Allied Telesis AlliedView-EMS 4.0.3 Device-Management User Manual
Page 214

AlliedView™-EMS 4.0.3 Device Management Guide
Page 214 of 468
Note
- The current firmware version returns the value 'NULL' for the OID
parameter.
LLDP MED
Device Info
Displays information which describe the device's behavior of the LLDP-MED.
MED Port Config
Displays the LLDP configuration information that controls the transmission
of the MED.
Note
- Device Manager does not handle objects of type BITS correctly. As a
result, the TLVs Tx Enable parameter will not be configurable and will display
an 8-bit binary string instead of the actual TLV types allowed. However, the
TLV types allowed can still be determined by looking at the bits that are on
from left to right:
•
Bit 0 - Port Description
•
Bit 1 - System Name
•
Bit 2 - System Description
•
Bit 3 - System Capabilities
Note
- Device Manager does not handle objects of type BITS correctly. As a
result, the MED TLVs Tx Enable parameter will not be configurable and will
display an 8-bit binary string instead of the actual TLV types allowed.
However, the TLV types allowed can still be determined by looking at the
bits that are on from left to right:
•
Bit 0 - Capabilities
•
Bit 1 - Network Policy
•
Bit 2 - Location
•
Bit 3 - Extended PSE
•
Bit 4 - Extended PD
•
Bit 5 - Inventory
Network Policy Info
Displays information about a particular policy on a specific port component.
Note
- Device Manager does not handle bit string correctly. As a result, the
Application Type parameter will not be displayed.
Location Info
Displays the Location information as advertised by the local system.
Note
- Device Manager always treats objects of type OCTET STRING as a
sequence of bytes in hexadecimal format and does not convert them to plain
text format when necessary. As a result, the Location parameter will neither
be readable nor configurable.