Allied Telesis AlliedView-EMS 4.0.3 Device-Management User Manual
Page 360

AlliedView™-EMS 4.0.3 Device Management Guide
Page 360 of 468
Additional Info
Displays additional information on the port's spanning tree parameters.
Note
- The current firmware version does not allow the Protocol Migration
parameter to be set to 'true'.
Note
- The current firmware version does not allow the Point-to-Point
Config parameter to be set to 'auto'.
Note
- Valid MIB Set values for the Port Path Cost Config parameter
is [1-200000000] inclusive. However, the current firmware version allows
the user to set this parameter to '0' as its value and will automatically set the
entered value to valid values.
Note
- The current firmware version does not allow the Protocol Migration,
Edge Port, Point-to-Point Config and Port Path Cost Config parameters to be
configured.
Note
- When multiple units of the AT-x900-12X series are stacked together,
the 'Base Ports' submenu is displayed even if the AT-XEM-STK is the only
installed XEM module in the device.
MAC Control Pause
Displays information about the MAC Control Pause function on a single ethernet-
like interface.
Note
- The current firmware version returns a 'noSuchName' value for the Received
Frames (HC) and Transmit Frames (HC) parameters.
Note
- The PAUSE Config parameter is implemented as 'read-only'.
Note
- When multiple units of the AT-x900-12X series are stacked together, the
'Base Ports' submenu is displayed even if the AT-XEM-STK is the only installed XEM
module in the device.
MAU Info
Displays interface-related MAU information for the port.
Note
- The MAU Status and Default MAU Type parameters are implemented as
'read-only'.
Note
- The MAU Type List parameter is not applicable to the AT-x900-12X series
and should be ignored.
Note
- The Mau Type List Bits and HC False Carriers parameters are not applicable
to the AT-x900-12X series and should be ignored.