Toolboxes Function Block ErrorID List
MotionWorks IEC61131-3 Toolboxes: 2013-09-13
576
10077
Cubic Spline maximum number of consecutive segments exceeded. DataType definition for
the Matrix could be increased if necessary.
10078
Formula 27 Error is reserved for errors with circle calculations.
10079
When using UserNoDwellModifiedConstant Velocity, there must be three contiguous
segments with the same formula code applied, and the master percentages must be
increasing.
10080
Formula 29 error.
10081
ControlData.DecisionPosition
10082
Mode Error. ControlData.Mode can only be 1 (one way cam) or 2 (two way cam).
10083
Unsupported Cubic Spline Sequence
10084
One of the Cam Tables has an invalid TableID
10086
MaxPosCorrection must be zero or positive, MaxNegCorrection must be or zero or negative.
10100
Both axes must be configured for the same axis type (Rotary / Linear) and if Rotary, they
must have the same Machine Cycle
10110
Too many tabs specified.
10111
Pitch between labels would be negative, need more spacing between tabs
10112
Tab mode must be specified as 1 (Tabbing) or 2 (Stamp).
10114
Incorrect cam table size (check the CamTable.Header.Datasize)
10116
Problem converting string data to the output buffer
10117
String Conversion Error already exists on the controller. Clear the alarm and try again.
10118
STRING_TO_BUF Conversion Error
10119
In the Data Structure, rows must be set greater than zero and columns must be set greater
than zero.
10120
File could not be opened.
10121
CSV file contains an unsupported version.
10123
Column Start Error. The data is corrupted.
10124
Unsupported Case condition.
10125
Conversion Error. Check the ErrorRow and ErrorCol outputs for details
10126
NoDataError - The End Of File was reached, but the record count is zero
10127
TooManyRecords - DataType is not large enough
10128
MaxNotDefined - User must set the maximum number of records that can be added to
structure.
10129
No Carriage return found in CSV buffer. The function searched the file for twice the length
of the specified buffer and was unable to find a carriage return indicating the end of a row.
Either the buffer size is too small, or the data is invalid.
10130
The center to co-ordinate distance for the two input co-ordinates are not the same
10131
Zero radius is invalid
10132
Only modes 0 (center + 2 co-ordinates) and 1 (radius + 2 coordinates) are supported
10133
The coordinates of the two data points are the same
10140
Must be greater than zero and less than 20
10150
Theta1 Below Minimum.