beautypg.com

Gantry_power, Parameters – Yaskawa MotionWorks IEC Toolboxes User Manual

Page 275

background image

Gantry Toolbox: Function Blocks

MotionWorks IEC61131-3 Toolboxes: 2013-09-13

262

Gantry_Power

This function block will enable or disable all axes configured as part of a gantry system. This block uses the

AxisControl

function block from the

PLCopen Toolbox

. If the gantry is configured with dual motors on the same

physical axis, then the secondary or prime axes are geared to the other axis in the same physical motion plane.

Parameters

*

Parameter

Data Type

Description

VAR_IN_OUT

V

Gantry

GantryStruct

Contains all information pertaining to a gantry system.

VAR_INPUT

Default

B

Enable

BOOL

The function will continue to execute while
enable is held high.

FALSE

V

ClearAlarm

BOOL

This input will clear any axis specific
alarms on the Gantry axes

FALSE

VAR_OUTPUT

V

XAxisErrorID

UINT

ErrorID on the X axis

V

YAxisErrorID

UINT

ErrorID on the Y axis