beautypg.com

Notes, Error description – Yaskawa MotionWorks IEC Toolboxes User Manual

Page 364

background image

Pack ML Toolbox: Function Blocks

MotionWorks IEC61131-3 Toolboxes: 2013-09-13

351

deactivated, commands will not be
sent down to the CM, for testing
purposes. Each bit corresponds to the
same number CM to deactivate.
(Example: to deactivate CM_3, set
CM_Mask.X3

VAR_OUTPUT

B

Valid

BOOL

Indicates that the outputs of the function are valid

B

Error

BOOL

Set high if error has occurred during the execution of
the function block. This output is cleared when
'Enable' goes low.

B

ErrorID

UINT

If Error is true, this output provides the Error ID.
This output is reset when 'Enable' goes low.

Notes

• See template documentation for further details on recommended usage.

Error Description

ErrorID

Meaning

0

No Error

12560

Invalid Equipment Module number

12561

Equipment Module not enable in the system

12562

Invalid number of enabled Control Modules in selected Equipment Module