Yaskawa MotionWorks IEC Toolboxes User Manual
Page 378

Pack ML Toolbox: Function Blocks
MotionWorks IEC61131-3 Toolboxes: 2013-09-13
365
enabled and active
EMs if it is a legal
transition from the
current machine state,
otherwise the
command will be
ignored
V
Cfg_RemoteModeCmd
DINT
The remotely
requested mode to
transition to
0
B
Inp_RemoteModeCmdChangeReq
BOOL
When this input is set,
the machine will
transition to the mode
set by
Cfg_RemoteModeCmd
if it is a legal
transition from the
current state of the
machine
FALSE
V
Inp_RemoteStateCmd
DINT
The remotely
requested state to
transition to
0
B
Inp_RemoteStateCmdChangeReq
BOOL
When this input is set,
the machine will
transition to the state
set by
Cfg_RemoteStateCmd
if it is a legal
transition from the
current state of the
machine
FALSE
VAR_OUTPUT
B
EnableOut
BOOL
Indicates that the outputs of the
function are valid
B
Clearing
BOOL
When this bit is set, the machine is
in the ‘Clearing’ state
B
Stopped
BOOL
When this bit is set, the machine is
in the ‘Stopped’ state
B
Starting
BOOL
When this bit is set, the machine is
in the ‘Starting’ state
B
Idle
BOOL
When this bit is set, the machine is
in the ‘Idle’ state
B
Suspended
BOOL
When this bit is set, the machine is
in the ‘Suspended’ state
B
Execute
BOOL
When this bit is set, the machine is
in the ‘Execute’ state