Pack ML Toolbox: Function Blocks
MotionWorks IEC61131-3 Toolboxes: 2013-09-13
353
Parameters
*
Parameter
Data Type
Description
VAR_IN_OUT
V
PML_States
Structure containing information about the
current state the machine is operating in
V
UnitMachine
Structure containing all the information
about the machines current state and mode
of operation for all EMs and CMs
VAR_INPUT
Default
B
Enable
BOOL
The function will continue to
execute while the enable is
held high
FALSE
V
EM_Number
INT
The EM number corresponding
to the EM in which this FB is
located
0
V
CM_Number
WORD
The CM number corresponding
to the CM in which this FB is
located
0
B
Aborting_Done
BOOL
Setting this bit indicates that
the current CM is done
‘Aborting’ and is ready to move
to the next state
FALSE
B
Stopping_Done
BOOL
Setting this bit indicates that
the current CM is done
‘Stopping’ and is ready to move
to the next state
FALSE
B
Clearing_Done
BOOL
Setting this bit indicates that
the current CM is done
‘Clearing’ and is ready to move
to the next state
FALSE
B
Resetting_Done
BOOL
Setting this bit indicates that
the current CM is done
‘Resetting’ and is ready to
move to the next state
FALSE
B
Starting_Done
BOOL
Setting this bit indicates that
the current CM is done
‘Starting’ and is ready to move
to the next state
FALSE
B
Holding_Done
BOOL
Setting this bit indicates that
the current CM is done
‘Holding’ and is ready to move
to the next state
FALSE
B
UnHolding_Done
BOOL
Setting this bit indicates that
the current CM is done
FALSE