Gantry_stop, Parameters – Yaskawa MotionWorks IEC Toolboxes User Manual

Page 279

background image

Gantry Toolbox: Function Blocks

MotionWorks IEC61131-3 Toolboxes: 2013-09-13

266

Gantry_Stop

This function block will execute the MC_Stop block for all axes configured as part of a gantry system.

Parameters

*

Parameter

Data Type

Description

VAR_IN_OUT

V

Gantry

GantryStruct

Contains all information pertaining to a gantry system.

VAR_INPUT

Default

B

Execute

BOOL

Upon the rising edge, all other function block
inputs are read and the function is initiated.
To modify an input, change the value and re-
trigger the execute input.

FALSE

VAR_OUTPUT

B

Done

BOOL

Set high when the commanded action has been completed
successfully. If another block takes control before the
action is completed, the Done output will not be set. This
output is reset when execute goes low.

B

Busy

BOOL

Set high upon the rising edge of the 'Execute' or 'Enable'
input, and reset if Done, CommandAborted, or Error is
true.

B

CommandAborted

BOOL

Set high if motion is aborted by another motion command
or MC_Stop. This output is cleared with the same behavior
as the Done output.

B

Error

BOOL

Set high if error has occurred during the execution of the
function block. This output is cleared when 'Execute' or
'Enable' goes low.

B

ErrorID

UINT

If Error is true, this output provides the Error ID. This