beautypg.com

Aes reference – Grass Valley Maestro Master Control Installation v.2.4.0 User Manual

Page 419

background image

MAESTRO Installation and Service Manual

419

Electrical

Audio Specifications

Audio Standard

AES-1992 (r1997) 1999-11-23 printing

Dolby E

Pass through

Standard

For NTSC, Dolby E Pass through is switched on line 10.
For PAL, Dolby E Pass through is switched on line 6.

Rear Panel Types

75 ohm (BNC connectors)
or
110 ohm (25-pin D connectors)

Audio Inputs

Signal Type

48 kHz AES3. All AES inputs will accept synchronous/asynchronous sig-
nals from 30 to 50 kHz sample rate. Dolby E must be synchronous with
video reference

Number and Type

4 stereo pairs, Background A
4 stereo pairs, Background B
4 stereo pairs, Audio Over A
4 stereo pairs, Audio Over B
4 stereo pairs, Monitoring

Audio Outputs

Signal Type

48 kHz AES3

Number and Type

AES: 8 channels standard, each with Program, Clean Feed, Metering, and
Monitoring

Embedded: 16 channels, each with Program, Clean Feed, and Preset

MADI: 16 channels, each with Program, Clean Feed, Preset, and Metering

Analog Audio

Requires external A-D/D-A converter

Embedded Audio

SMPTE 272M (SD) and SMPTE 299M (HD)

AES Reference

Sample rate

48 kHz sample rate only. Use of AES reference is recommended for all
applications except Dolby E systems (Dolby E uses the video reference).
Using the AES reference preserves correct audio phasing in multi-channel
systems.

Connector

BNC, looping, 1 V.
Note: when not in use, this connector must be terminated.

Control

LAN

10/100 Ethernet: 2 ports – one for facility LAN, one for control LAN

Console RS-232 Serial

Two: One DB-9F connector port on rear panel, one at front edge of Proces-
sor PCB, connected in parallel

Automation RS-422

One DB-9F connector port

Tally

Via GPIO port:

Source tally mode for Encore and Jupiter-controlled systems (16 contact
closures maximum). Current source required for each tally lamp; 24 V, 250
mA maximum.

Bus tally mode for Jupiter/MI-3040 systems (40 tally lights per MI-3040)

Router Control

RS-422, One DB-9F connector port.

Meta Data

Automatic switching of Dolby E metadata arriving with background audio A
and B to the Program, Clean Feed 1, and Monitor outputs. Note: the func-
tions of this connector are not yet implemented.

Table 18. Electrical Specifications