beautypg.com

Grass Valley Maestro Master Control Installation v.2.4.0 User Manual

Page 145

background image

MAESTRO Installation and Service Manual

145

1st Step: Connections

Jupiter serial - select “1.”

Jupiter LAN - no entry.

Parity

Enter the Parity for the Jupiter serial connection.

Encore and Prelude - no entry.

Jupiter serial - select “ODD.”

Jupiter LAN - no entry.

Switch Frame Delay

(Required entry) - Enter the control system switch latency in frames. The
following are default values.

Encore and Prelude - 12.

Jupiter CM-4000/AccuSwitch - 2

Jupiter CM-4000/JupiterXPress - 4

Jupiter VM-3000 - 6

Note

These values are system-dependent. The above defaults are suggested in
advance of empirical testing using specific systems under defined condi-
tions.

ES-Control RCS Device Name

Encore and Prelude - no entry.

Jupiter - Select the name of the appropriate configuration set to be used
with Maestro. The source of these names is the Jupiter MPK Devices table.
If you do not see the names expected on the drop-down list, it may be that
the connection to the control system server has not been established. By
selecting “Connect to Server” the editor will retrieve configuration data
already entered on the router control system.

For example, if the router control system is Jupiter, a screen similar to the
following screen will appear: