beautypg.com

Grass Valley Maestro Master Control Installation v.2.4.0 User Manual

Page 211

background image

MAESTRO Installation and Service Manual

211

5th Step: Input/Output Sets

IP address. The RCS Level is selected from a list of all router levels defined
in the router control system and made available for use in Maestro.

RCS Input

A named router input (as defined in the selected Router Control System
Level) to which the source to be switched to the preferred monitor is con-
nected.

RCS Output

A named router output (as defined in the selected Router Control System
Level) which is connected to the monitor to which the designated source
input should be switched. This switch will take place when a channel del-
egation operation is performed.

Refresh

If this box is checked, the router inputs and outputs will be refreshed
approximately every 15 seconds and the designated routes will be re-estab-
lished if they have changed.

Note

If post-delegation operator control of what is routed to the monitors is pre-
ferred, this box should not be checked. With the box unchecked, a routing of
monitor outputs as defined in the Monitor Follow table would take place on
initial channel delegation; however, the operator could perform manual
routes to the monitor outputs after the delegation operation. Maestro would
only re-establish the Monitor Follow configured routes upon execution of
another channel delegation operation.

Monitor Follow Configuration Examples

Figure 116

shows a sample Monitor Follow configuration for an SD channel

with stereo audio.