MAESTRO Installation and Service Manual

Section 6 — Deployment Control Center

f.

From this point there are two possibilities:

A popup will show that the Processor update was successful.

Repeat

Step 1

above if another Processor is present. Otherwise,

go to

Step 2

below.

An error message may indicate that the “physical JTAG chain is

broken.” If this message appears, the FPGAs/CPLDs on the Pro-
cessor cannot be updated. Discontinue the v2.4.0 installation
and contact Technical Support.

2.

Updating FPGAs/CPLDs on the hardware control panel(s):

a.

In the board Status section of the screen, select the hardware control
panel to update.

b.

Right-click on the FPGA field for this control panel.

This will display the FPGA/CPLD update menu. See

Figure 167

Figure 167. Control Panel FPGA/CPLD Update Menu

This menu shows the names of all FPGAs/CPLDs on the control
panel and the version number of the gateware now running
(“loaded”) in each device. Certain FPGA-type components and all
of the CPLD-type components can be updated using this menu, and
if a newer (“current”) version of gateware is available for those
components the menu will indicate the new version number and
display a check box.

c.

Check the “Select All” box.

d.

Select

Update

.

You will be asked to confirm the update.