Rockwell Automation 21G PowerFlex 750-Series AC Drives Programming Manual User Manual
Page 64

64
Rockwell Automation Publication 750-PM001J-EN-P - October 2014
Chapter 3
Drive Port 0 Parameters
M
O
TO
R C
O
N
TROL
A
uto
tu
n
e
1630
IPM_Lq_25_pct
Lq for 25% Iq IPM Control
Sets Lq at 25% current.
Units:
Default:
Min/Max:
mH
0.00
0.00 / 999990.00
RW Real
1631
IPM_Lq_50_pct
Lq for 50% Iq IPM Control
Sets Lq at 50% current.
Units:
Default:
Min/Max:
mH
0.00
0.00 / 999990.00
RW Real
1632
IPM_Lq_75_pct
Lq for 75% Iq IPM Control
Sets Lq at 75% current.
Units:
Default:
Min/Max:
mH
0.00
0.00 / 999990.00
RW Real
1633
IPM_Lq_100_pct
Lq for 100% Iq IPM Control
Sets Lq at 100% current.
Units:
Default:
Min/Max:
mH
0.00
0.00 / 999990.00
RW Real
1634
IPM_Lq_125_pct
Lq for 125% Iq IPM Control
Sets Lq at 125% current.
Units:
Default:
Min/Max:
mH
0.00
0.00 / 999990.00
RW Real
1635
IPM_Ld_0_pct
Ld for 0% Id IPM Control
Sets Ld at 0% current.
Units:
Default:
Min/Max:
mH
0.00
0.00 / 999990.00
RW Real
1636
IPM_Ld_100_pct
Ld for 100% Id IPM Control
Sets Ld at 100% current.
Units:
Default:
Min/Max:
mH
0.00
0.00 / 999990.00
RW Real
1646
IPM PriOffstComp
IPM Primary Encoder Offset Compensation
Primary Offset Compensation, AutoTune group.
Default:
Min/Max:
0
0 / 512
RW Real
1647
IPM AltOffstComp
IPM Alternate Encoder Offset Compensation
Alternate Offset Compensation, AutoTune group.
Default:
Min/Max:
0
0 / 512
RW Real
Fi
le
Grou
p
No.
Display Name
Full Name
Description
Values
Re
ad
-W
ri
te
Da
ta
T
ype