Embedded Feature and Option Module Parameters
Chapter 5
Fil
e
Gr
ou
p
No.
Display Name
Full Name
Description
Values
Re
ad
-Write
Da
ta T
ype
11
-S
er
ies I/O
An
al
og O
u
tpu
ts
70
Anlg Out Type
Analog Output Type
RW 16-bit
Integer
Select the analog output mode for each analog output.
71
Anlg Out Abs
Analog Output Absolute
RW 16-bit
Integer
Selects whether the signed value or absolute value of a parameter is used before being scaled to drive the analog output.
75
Anlg Out0 Sel
Analog Output 0 Select
Selects the source for the analog output.
Default:
Min/Max:
3
0 / 159999
RW 32-bit
Integer
76
Anlg Out0 Stpt
Analog Output 0 Setpoint
A possible source for an analog output. Can be used to control an analog output from a
communication device using a DataLink. Not affected by analog output scaling.
Units:
Default:
Min/Max:
Volt
mA
10.000 Volts
20.000 mA
–/+10.000 Volts
0.000 / 20.000 mA
RW Real
77
Anlg Out0 Data
Analog Output 0 Data
Displays the value of the source selected by P75 [Anlg Out0 Sel].
Default:
Min/Max:
0
–/+100000
RO
Real
78
Anlg Out0 DataHi
Analog Output 0 Data High
Sets the high value for the data range of analog out scale.
Units:
Default:
Min/Max:
pu
1
–/+21474800
RW Real
79
Anlg Out0 DataLo
Analog Output 0 Data Low
Sets the low value for the data range of analog out scale.
Default:
Min/Max:
1
–/+21474800
RW Real
80
Anlg Out0 Hi
Analog Output 0 High
Sets the high value for the analog output value when the data value is at its maximum.
Units:
Default:
Min/Max:
Volt
mA
10.000 Volts
20.000 mA
–/+10.000 Volts
0.000 / 20.000 mA
RW Real
81
Anlg Out0 Lo
Analog Output 0 Low
Sets the low value for the analog output value when the data value is at its minimum.
Units:
Default:
Min/Max:
Volt
mA
10.000 Volts
20.000 mA
–/+10.000 Volts
0.000 / 20.000 mA
RW Real
Options
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
An
al
og
0
Default
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bit
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
0 = Voltage Mode
1 = Current Mode
Options
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Re
se
rv
ed
Analog 0
Default
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
Bit
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
0 = Condition False
1 = Condition True