How drive parameters are organized, Basic parameter view (port 0) – Rockwell Automation 21G PowerFlex 750-Series AC Drives Programming Manual User Manual
Page 24

24
Rockwell Automation Publication 750-PM001J-EN-P - October 2014
Chapter 2
Parameter Organization
How Drive Parameters are
Organized
DriveExecutive programming software displays parameters in “Linear List” or
“File Group Parameter” format. Viewing the parameters in “File Group
Parameter” format simplifies programming by grouping parameters that are used
for similar functions. There are eleven files. Each file is divided into multiple
groups of parameters.
Drive (Port 0) parameter descriptions begin on
Basic Parameter View (Port 0)
Parameter 301 [Access Level] set to option 0 “Basic.”
File
Group
Parameters
Monitor
Metering
Output Frequency
1
Commanded SpdRef
2
Mtr Vel Fdbk
3
Commanded Trq
4
Torque Cur Fdbk
5
Flux Cur Fdbk
6
Output Current
7
Output Voltage
8
Output Power
9
DC Bus Volts
11
Drive Data
Rated Volts
20
Rated Amps
21
Rated kW
22
Motor Control
Motor Data
Motor NP Volts
25
Motor NP Amps
26
Motor NP Hertz
27
Motor NP RPM
28
Mtr NP Pwr Units
29
Motor NP Power
30
Motor Poles
31
Mtr Ctrl Options
Motor Ctrl Mode
35
Maximum Voltage
36
Maximum Freq
37
PWM Frequency
38
IPM Stc OfsTst K
(1)
1660
(1) Frames 1…7 Only
Volts per Hertz
VHz Curve
65
Autotune
Autotune
70
Autotune Torque
71
IPM_Lg_25_pct
1630
IPM_Lg_50_pct
1631
IPM_Lg_75_pct
1632
IPM_Lg_100_pct
1633
IPM_Lg_125_pct
1634
IPM_Ld_0_pct
1635
IPM_Ld_100_pct
1636
Feedback & I/O
Digin Functions
Digital In Cfg
150
DI Enable
155
DI Clear Fault
156
DI Aux Fault
157
DI Stop
158
DI Cur Lmt Stop
159
DI Coast Stop
160
DI Start
161
DI Fwd Reverse
162
DI Run
163
DI Run Forward
164
DI Run Reverse
165
DI Jog 1
166
DI Jog 1 Forward
167
DI Jog 1 Reverse
168
DI Jog 2
169
DI Jog 2 Forward
170
DI Jog 2 Reverse
171
DI Manual Ctrl
172
DI Speed Sel 0
173
DI Speed Sel 1
174
DI Speed Sel 2
175
DI HOA Start
176
DI Accel 2
179
DI Decel 2
180
Control Board IO
755
Digital In Sts
220
Digital Inputs
753
Digital In Sts
220
Dig In Filt Mask
222
Dig In Filt
223
Digital Outputs
753
Dig Out Sts
225
Dig Out Invert
226
RO0 Sel
230
RO0 Level Sel
231
RO0 Level
232
RO0 Level CmpSts
233
TO0 Sel
240
TO0 Level Sel
241
TO0 Level
242
TO0 Level CmpSts
243
Motor PTC
753
PTC Cfg
250
PTC Status
251
Analog Inputs
753
Anlg In Type
255
Anlg In0 Value
260
Anlg In0 Hi
261
Anlg In0 Lo
262
Analog Outputs
753
Anlg Out Type
270
Anlg Out0 Sel
275
Anlg Out0 Data
277
Anlg Out0 DataHi
278
Anlg Out0 DataLo
279
Anlg Out0 Hi
280
Anlg Out0 Lo
281
Anlg Out0 Val
282
Monit
or
Motor Con
trol
Feedback and IO