Rockwell Automation 21G PowerFlex 750-Series AC Drives Programming Manual User Manual
Page 352

352
Rockwell Automation Publication 750-PM001J-EN-P - October 2014
Chapter 6
Troubleshooting
xx072
Ch0 ROM Error
Configurable
P9
[FB0 Loss Cfg]
Error reported by a linear Stahl encoder on Channel 0 - Indicates a ROM
error. Reading head needs to be repaired
xx074
Ch0 No Position
Configurable
P9
[FB0 Loss Cfg]
Error reported by a linear Stahl encoder on Channel 0 - Indicates that no
position value was available - only possible following powerup or reset
xx081
Ch0 Msg Cheksum
Configurable
P9
[FB0 Loss Cfg]
Indicates the option card has detected a serial communications
checksum error while attempting to communicate with the encoder on
channel 0.
xx082
Ch0 Timeout
Configurable
P9
[FB0 Loss Cfg]
Indicates the option card has detected a serial communications timeout
error while attempting to communicate with the encoder on channel 0.
xx083
Ch0 Comm
Configurable
P9
[FB0 Loss Cfg]
Indicates the option card has detected a serial communications error
(other than checksum or timeout) while attempting to communicate
with the encoder on channel 0.
xx084
Ch0 Diagnostic
Configurable
P9
[FB0 Loss Cfg]
Indicates the option card has detected a powerup diagnostic test failure
for encoder channel 0.
xx085
Ch0 SpplyVltgRng
Configurable
P9
[FB0 Loss Cfg]
Indicates that the voltage source to the encoder 0 is out of range.
xx086
Ch0 SC Amplitude
Configurable
P9
[FB0 Loss Cfg]
Indicates that the encoder 0 signal amplitude is out of tolerance.
xx087
Ch0 Open Wire
Configurable
P9
[FB0 Loss Cfg]
Indicates that an open wire condition has been detected for encoder 0.
Both Sine and Cosine signals fell below 0.3 volts.
xx088
Ch0 Quad Loss
Configurable
P9
[FB0 Loss Cfg]
Indicates that a signal quadrature error has been detected for encoder 0.
Add ferite cores.
xx089
Ch0 Phase Loss
Configurable
P9
[FB0 Loss Cfg]
Indicates that an A or B signal of an A quad B incremental encoder on
Channel 0 is disconnected.
xx090
Ch0 Unsupp Enc
Configurable
P9
[FB0 Loss Cfg]
Indicates that the connected encoder on Channel 0 is not supported
xx100
Ch0 FreqExc Alm
Alarm 1
P9
[FB0 Loss Cfg]
Alarm reported by Heidenhain Encoder on Channel 0 with EnDat
Interface - Frequency exceeded warning
xx101
Ch0 TempExc Alm
Alarm 1
P9
[FB0 Loss Cfg]
Alarm reported by Heidenhain Encoder on Channel 0 with EnDat
Interface - Temperature exceeded warning
xx102
Ch0 LightLim Alm
Alarm 1
P9
[FB0 Loss Cfg]
Alarm reported by Heidenhain Encoder on Channel 0 with EnDat
Interface - Limit of light control reserve reached
xx103
Ch0 Battery Alm
Alarm 1
P9
[FB0 Loss Cfg]
Alarm reported by Heidenhain Encoder on Channel 0 with EnDat
Interface - Battery warning
xx104
Ch0 RefPoint Alm
Alarm 1
P9
[FB0 Loss Cfg]
Alarm reported by Heidenhain Encoder on Channel 0 with EnDat
Interface - Reference point not reached
xx108
Ch0 General Alm
Alarm 1
P9
[FB0 Loss Cfg]
Alarm reported by a Encoder on Channel 0 with BiSS Interface - A
warning bit of the BiSS Single Cycle Data is set
xx115
Ch0 Optics Alarm
Alarm 1
P9
[FB0 Loss Cfg]
Alarm reported by a linear Stahl encoder on Channel 0 - Displays an
alarm when the Stahl optical system requires cleaning
xx116
Ch0 OutOfRailAlm
Alarm 1
P9
[FB0 Loss Cfg]
Alarm reported by a linear Stahl encoder on Channel 0 - Indicates that
the read encoder count is at the maximum value (524287)
xx200
Ch1 LightSrc Err
Configurable
P39
[FB1 Loss Cfg]
Error reported by Heidenhain Encoder on Channel 1 with EnDat Interface
- Light source failure
xx201
Ch1 SigAmp Err
Configurable
P39
[FB1 Loss Cfg]
Error reported by Heidenhain Encoder on Channel 1 with EnDat Interface
-Signal amplitude error
xx202
Ch1 PsnVal Err
Configurable
P39
[FB1 Loss Cfg]
Error reported by Heidenhain Encoder on Channel 1 with EnDat Interface
- Position value error
xx203
Ch1 OverVolt Err
Configurable
P39
[FB1 Loss Cfg]
Error reported by Heidenhain Encoder on Channel 1 with EnDat Interface
- Overvoltage error
Event
No.
(1)
Fault/Alarm Text
Type
Fault
Action
Configuration Param
Auto
Reset
Description