beautypg.com

Rockwell Automation 21G PowerFlex 750-Series AC Drives Programming Manual User Manual

Page 353

background image

Rockwell Automation Publication 750-PM001J-EN-P - October 2014

353

Troubleshooting

Chapter 6

xx204

Ch1 UndVolt Err

Configurable

P39
[FB1 Loss Cfg]

Error reported by Heidenhain Encoder on Channel 1 with EnDat Interface
- Undervoltage error

xx205

Ch1 OverCur Err

Configurable

P39
[FB1 Loss Cfg]

Error reported by Heidenhain Encoder on Channel 1 with EnDat Interface
- Overcurrent error

xx206

Ch1 Battery Err

Configurable

P39
[FB1 Loss Cfg]

Error reported by Heidenhain Encoder on Channel 1 with EnDat Interface
- Battery empty

xx209

Ch1 AnalSig Err

Configurable

P39
[FB1 Loss Cfg]

Error reported by Stegmann Encoder on Channel 1 with Hiperface
Interface - Analog signals outside specification

xx210

Ch1 IntOfst Err

Configurable

P39
[FB1 Loss Cfg]

Error reported by Stegmann Encoder on Channel 1 with Hiperface
Interface - Faulty internal angular offset

xx211

Ch1 DataTabl Err

Configurable

P39
[FB1 Loss Cfg]

Error reported by Stegmann Encoder on Channel 1 with Hiperface
Interface - Data field partitioning table damaged

xx212

Ch1 AnalLim Err

Configurable

P39
[FB1 Loss Cfg]

Error reported by Stegmann Encoder on Channel 1 with Hiperface
Interface - Analog limit values not available

xx213

Ch1 Int I2C Err

Configurable

P39
[FB1 Loss Cfg]

Error reported by Stegmann Encoder on Channel 1 with Hiperface
Interface - Internal I2C bus not operational

xx214

Ch1 IntChksm Err

Configurable

P39
[FB1 Loss Cfg]

Error reported by Stegmann Encoder on Channel 1 with Hiperface
Interface - Internal checksum error

xx215

Ch1 PrgmResetErr

Configurable

P39
[FB1 Loss Cfg]

Error reported by Stegmann Encoder on Channel 1 with Hiperface
Interface - Encoder reset occurred as a result of program monitoring

xx216

Ch1 CntOvrflwErr

Configurable

P39
[FB1 Loss Cfg]

Error reported by Stegmann Encoder on Channel 1 with Hiperface
Interface - Counter overflow

xx217

Ch1 Parity Err

Configurable

P39
[FB1 Loss Cfg]

Error reported by Stegmann Encoder on Channel 1 with Hiperface
Interface - Parity error

xx218

Ch1 Chksum Err

Configurable

P39
[FB1 Loss Cfg]

Error reported by Stegmann Encoder on Channel 1 with Hiperface
Interface - Checksum of the data transmitted is incorrect

xx219

Ch1 InvCmd Err

Configurable

P39
[FB1 Loss Cfg]

Error reported by Stegmann Encoder on Channel 1 with Hiperface
Interface - Unknown command code

xx220

Ch1 SendSize Err

Configurable

P39
[FB1 Loss Cfg]

Error reported by Stegmann Encoder on Channel 1 with Hiperface
Interface - Number of data transmitted is incorrect

xx221

Ch1 CmdArgmt Err

Configurable

P39
[FB1 Loss Cfg]

Error reported by Stegmann Encoder on Channel 1 with Hiperface
Interface - Command argument transmitted is not allowed

xx222

Ch1 InvWrtAdrErr

Configurable

P39
[FB1 Loss Cfg]

Error reported by Stegmann Encoder on Channel 1 with Hiperface
Interface - The selected data field must not be written to (invalid write
address)

xx223

Ch1 AccCode Err

Configurable

P39
[FB1 Loss Cfg]

Error reported by Stegmann Encoder on Channel 1 with Hiperface
Interface - Incorrect access code

xx224

Ch1 FieldSizeErr

Configurable

P39
[FB1 Loss Cfg]

Error reported by Stegmann Encoder on Channel 1 with Hiperface
Interface - Size of data field stated cannot be changed

xx225

Ch1 Address Err

Configurable

P39
[FB1 Loss Cfg]

Error reported by Stegmann Encoder on Channel 1 with Hiperface
Interface - Word address stated is outside data field

xx226

Ch1 FieldAcc Err

Configurable

P39
[FB1 Loss Cfg]

Error reported by Stegmann Encoder on Channel 1 with Hiperface
Interface - Access to non-existent data field

xx228

Ch1 SiTurnPsnErr

Configurable

P39
[FB1 Loss Cfg]

Error reported by Stegmann Encoder on Channel 1 with Hiperface
Interface - Single turn position unreliable

xx229

Ch1 MulTrnPsnErr

Configurable

P39
[FB1 Loss Cfg]

Error reported by Stegmann Encoder on Channel 1 with Hiperface
Interface - Multiple turn position unreliable

xx236

Ch1 AnalVal Err

Configurable

P39
[FB1 Loss Cfg]

Error reported by Stegmann Encoder on Channel 1 with Hiperface
Interface - Analog value error (process data)

Event
No.

(1)

Fault/Alarm Text

Type

Fault
Action

Configuration Param

Auto
Reset

Description