Rockwell Automation 21G PowerFlex 750-Series AC Drives Programming Manual User Manual
Page 185

Rockwell Automation Publication 750-PM001J-EN-P - October 2014
185
Drive Port 0 Parameters
Chapter 3
APPLIC
AT
IO
NS
Pump O
ff
1196
Pump Off Speed
Pump Off Speed
Sets the percent drop in speed from the commanded speed during a pump off condition.
Units:
Default:
Min/Max:
%
20.00
0.00 / 100.00
RW Real
1197
Pump Off Time
Pump Off Time
Sets the time the drive will run at the reduced P1196 [Pump Off Speed] before returning
to the commanded speed and checking if the pump off condition still exists.
Units:
Default:
Min/Max:
Secs
600.00
120.00 / 60000.00
RW Real
1198
Pct Cycle Torque
Percent Cycle Torque
Displays the average torque for a full pump cycle.
Units:
Default:
Min/Max:
%
0.00
-100.00 / 200.00
RO
Real
1199
Pct Lift Torque
Percent Lift Torque
Displays the average rod lift torque.
Units:
Default:
Min/Max:
%
0.00
-100.00 / 200.00
RO
Real
1200
Pct Drop Torque
Percent Drop Torque
Displays the average rod dropping torque.
Units:
Default:
Min/Max:
%
0.00
-100.00 / 200.00
RO
Real
1201
Stroke Pos Count
Stroke Position Count
Displays the pump cycle position. The top of stroke should be 0 and rolls over at 10,000.
Default:
Min/Max:
0
0 / 15000
RO
32-bit
Integer
1202
Stroke Per Min
Stroke Per Minute
Displays the strokes per minute.
Default:
Min/Max:
0.00
0.00 / 50.00
RO
Real
1203
Pump Off Count
Pump Off Count
Displays the number of times a pump off condition has occurred since this parameter
was reset.
Default:
Min/Max:
0.00
0.00 / 60000.00
RW Real
1204
PumpOff SleepCnt
Pump Off Sleep Count
Displays the number of times a sleep condition has occurred since this parameter was
reset.
Default:
Min/Max:
0.00
0.00 / 60000.00
RW Real
1205
Day Stroke Count
Day Stroke Count
Displays the number of strokes for the past 24 hours. This is a rolling counter updated
every hour.
Default:
Min/Max:
0.00
0.00 / 65535.00
RO
Real
1206
DI PumpOff Disbl
Digital Input Pump Off Disable
Selects the digital input source for the Pump Off Disable function.
Default:
Min/Max:
0.00
0.00 / 159999.15
RW 32-bit
Integer
1207
Pump OffSleepLvl
Pump Off Sleep Level
Provides a source for P351 [SleepWake RefSel]. This provides the start/stop control of
the drive by the pump off function.
Units:
Default:
Min/Max:
Volt
0.00
0.00 / 10.00
RO
Real
Fi
le
Grou
p
No.
Display Name
Full Name
Description
Values
Re
ad
-W
ri
te
Da
ta
T
ype