Rockwell Automation 21G PowerFlex 750-Series AC Drives Programming Manual User Manual
Page 354
354
Rockwell Automation Publication 750-PM001J-EN-P - October 2014
Chapter 6
Troubleshooting
xx237
Ch1 SendCurr Err
Configurable
P39
[FB1 Loss Cfg]
Error reported by Stegmann Encoder on Channel 1 with Hiperface
Interface - Transmitter current critical (dirt, broken transmitter)
xx238
Ch1 EncTemp Err
Configurable
P39
[FB1 Loss Cfg]
Error reported by Stegmann Encoder on Channel 1 with Hiperface
Interface - Encoder temperature critical
xx239
Ch1 Speed Err
Configurable
P39
[FB1 Loss Cfg]
Error reported by Stegmann Encoder on Channel 1 with Hiperface
Interface - Speed too high, no position formation possible
xx240
Ch1 General Err
Configurable
P39
[FB1 Loss Cfg]
Error reported by a Encoder on Channel 1 with BiSS Interface - An error
bit of the BiSS Single Cycle Data is set
xx246
Ch1 LED Curr Err
Configurable
P39
[FB1 Loss Cfg]
Error reported by a Encoder on Channel 1 with BiSS Interface - LED
current out of control range
xx247
Ch1 ExMulTurnErr
Configurable
P39
[FB1 Loss Cfg]
Error reported by a Encoder on Channel 1 with BiSS Interface - External
multiturn error
xx248
Ch1 PsnCode Err
Configurable
P39
[FB1 Loss Cfg]
Error reported by a Encoder on Channel 1 with BiSS Interface - Position
code error (single step error)
xx249
Ch1 Config Err
Configurable
P39
[FB1 Loss Cfg]
Error reported by a Encoder on Channel 1 with BiSS Interface - failure
configuring interface
xx250
Ch1 PsnVal Err
Configurable
P39
[FB1 Loss Cfg]
Error reported by a Encoder on Channel 1 with BiSS Interface - Position
data not valid
xx251
Ch1 SerialComErr
Configurable
P39
[FB1 Loss Cfg]
Error reported by a Encoder on Channel 1 with BiSS Interface - Serial
interface failure
xx252
Ch1 Ext Failure
Configurable
P39
[FB1 Loss Cfg]
Error reported by a Encoder on Channel 1 with BiSS Interface - External
failure over NERR
xx253
Ch1 Temp Exc Err
Configurable
P39
[FB1 Loss Cfg]
Error reported by a Encoder on Channel 1 with BiSS Interface -
Temperature out of defined range
xx256
Ch1 OutOfRailErr
Configurable
P39
[FB1 Loss Cfg]
Error reported by a linear Stahl encoder on Channel 1 - Rail is no longer
present between the read head
xx260
Ch1 Read Head 1
Configurable
P39
[FB1 Loss Cfg]
Error reported by a linear Stahl encoder on Channel 1 - Indicates that the
read head must be cleaned or installed correctly
xx261
Ch1 Read Head 2
Configurable
P39
[FB1 Loss Cfg]
Error reported by a linear Stahl encoder on Channel 1 - Indicates that the
read head must be cleaned or installed correctly
xx262
Ch1 RAM Error
Configurable
P39
[FB1 Loss Cfg]
Error reported by a linear Stahl encoder on Channel 1 - Indicates a RAM
error. Reading head needs to be repaired
xx263
Ch1 EPROM Error
Configurable
P39
[FB1 Loss Cfg]
Error reported by a linear Stahl encoder on Channel 1 - Indicates a
EPROM error. Reading head needs to be repaired
xx264
Ch1 ROM Error
Configurable
P39
[FB1 Loss Cfg]
Error reported by a linear Stahl encoder on Channel 1 - Indicates a ROM
error. Reading head needs to be repaired
xx266
Ch1 No Position
Configurable
P39
[FB1 Loss Cfg]
Error reported by a linear Stahl encoder on Channel 1 - Indicates that no
position value was available - only possible following powerup or reset
xx281
Ch1 Msg Cheksum
Configurable
P39
[FB1 Loss Cfg]
Indicates the option card has detected a serial communications
checksum error while attempting to communicate with the encoder on
channel 1.
xx282
Ch1 Timeout
Configurable
P39
[FB1 Loss Cfg]
Indicates the option card has detected a serial communications timeout
error while attempting to communicate with the encoder on channel 1.
xx283
Ch1 Comm
Configurable
P39
[FB1 Loss Cfg]
Indicates the option card has detected a serial communications error
(other than checksum or timeout) while attempting to communicate
with the encoder on channel 1.
xx284
Ch1 Diagnostic
Configurable
P39
[FB1 Loss Cfg]
Indicates the option card has detected a powerup diagnostic test failure
for encoder channel 1.
xx285
Ch1 SpplyVltgRng
Configurable
P39
[FB1 Loss Cfg]
Indicates that the voltage source to the encoder 1 is out of range.
Event
No.
(1)
Fault/Alarm Text
Type
Fault
Action
Configuration Param
Auto
Reset
Description