Rockwell Automation 21G PowerFlex 750-Series AC Drives Programming Manual User Manual
Page 169

Rockwell Automation Publication 750-PM001J-EN-P - October 2014
169
Drive Port 0 Parameters
Chapter 3
964
See
.
Fi
le
Gr
ou
p
No.
Display Name
Full Name
Description
Values
Re
ad
-Write
Da
ta T
ype
DIA
G
NOSTICS
Te
st
po
in
ts
970
974
978
982
Testpoint Sel 1
Testpoint Sel 2
Testpoint Sel 3
Testpoint Sel 4
Testpoint Select n
Selects a source for the testpoint values (“Fval” and “Lval”). Used by the factory, typically
for diagnostic purposes.
Default:
Min/Max:
0
–2147483648 / 2147483647
RW 32-bit
Integer
971
975
979
983
Testpoint Fval 1
Testpoint Fval 2
Testpoint Fval 3
Testpoint Fval 4
Testpoint Float Value n
Displays data selected by [Testpoint Sel n], if the data type is floating point.
Default:
Min/Max:
0.000000
–/+ 220000000.000000
RW Real
972
976
980
984
Testpoint Lval 1
Testpoint Lval 2
Testpoint Lval 3
Testpoint Lval 4
Testpoint Long Value n
Displays data selected by [Testpoint Sel n], if the data type is long integer.
Default:
Min/Max:
0
–2147483648 / 2147483647
RW 32-bit
Integer
Fil
e
Gr
ou
p
No.
Display Name
Full Name
Description
Values
Re
ad
-Write
Da
ta
T
yp
e
DIA
G
NOSTICS
Pe
ak
D
et
ec
ti
on
1035
PkDtct Stpt Real
Peak Detection Setpoint Real
A setpoint value, in the form of a real number. Intended to be used as a potential data
source for P1038 [PkDtct1PresetSel] and P1043 [PkDtct2PresetSel].
Default:
Min/Max:
0.000000
–/+ 220000000.000000
RW Real
1036
PkDtct Stpt DInt
Peak Detection Setpoint D Integer
A setpoint value, in the form of an integer number. Intended to be used as a potential
data source for P1038 [PkDtct1PresetSel] and P1043 [PkDtct2PresetSel].
Default:
Min/Max:
0
–2147483648 / 2147483647
RW 32-bit
Integer
1037
PkDtct1 In Sel
Peak Detection 1 Input Select
Selects the input data source for the peak detect functions. The functions can be
configured to sample and hold either the largest (maximum) or smallest (minimum)
value of the input signal selected by this parameter.
Important: Either real or integer data sources can be selected, but integer sources will
be internally converted to real and displayed in the peak detect output as real numbers.
Default:
Min/Max:
1035
0 / 15999931
RW 32-bit
Integer
1038
PkDtct1PresetSel
Peak Detection 1 Preset Select
Selects the preset data source for the peak detect functions. The output of the each peak
detect function can be forced to equal the value of the input signal selected by this
parameter by using the”Peak1 Set” bit in P1039 [Peak1 Cfg]. The same integer to real
number conversion applies to both the input and the preset signal.
Default:
Min/Max:
0
0 / 15999931
RW 32-bit
Integer
755
755
755
755